International Journal of Chemical and Biochemical Sciences (ISSN 2226-9614)[/vc_column_text][/vc_column][/vc_row]
VOLUME 26(20) (2024)
RP-HPLC-UV method validation for Ribavirin used in topical applications
Muhammad Hamza1,2, Qudsia Kanwal1*, Ahmad Raza3, Komal Zehra3, Muhammad Yasir1*, Dur e Najaf Iqbal1, Nuzhat Jamil4, Muhammad Muddassar Afzal5, Mudasir Majeed6, Muhammad Zubair Kamran1
1Department of Chemistry, The University of Lahore, Lahore, Pakistan
2Additive Manufacturing Institute, Shenzhen University, Shenzhen, China
3Department of Chemistry, Superior University, 17Km Raiwind Road, Kot Araian, Lahore, Pakistan
4Nanotechnology Division, National Institute for Biotechnology and Genetic Engineering (NIBGE), Faisalabad, Pakistan
5Department of Chemistry, University of Education, Lahore, Faisalabad Campus, Pakistan
6Department of Applied Chemistry, Government College University, Faisalabad, Pakistan
Abstract
In this research paper, accurate, cost effective and a straightforward reverse phase- High Performance Liquid Chromatography process was established and verified for the estimation of Ribavirin in topical dosage form. Chromatography separation technique was done on USP L17 (4.6mm×15cm) column possessing particles size of 5µm with liquid mobile phase consisting of sulfuric acid to a pH of 2.5±0.1 having column temperature 65±0.5ºC. Flow rate was kept 1mL per min. Estimation of ribavirin was done at 207nm with the help of UV-detector. Linearity was performed for Ribavirin and calibration curve was obtained which is linear for which is well within the limit. The method is developed & verified for accuracy, precision, linearity, range, specificity, and limit of detection (LOD), limit of quantization (LOQ), ruggedness & robustness. A simple, green, cost & time effective, robust and precise HPLC procedure for estimation of ribavirin was established. This procedure was then verified according to ICH guidelines Q2 (R1) Validation of Analytical methods. Ribavirin was determined accurately and precisely in topical dosage form. Overall this method wasdeveloped and performed for the determination of ribavirin amount in any dosage form within 2 minutes in a precise and accurate way.
Keywords: RP-HPLC-UV, Method validation, Isocratic elution, Ribavirin, Dermatitis.
Full length article – PDF *Qudsia Kanwal, e-mail: qudsia.kanwal@chem.uol.edu.pk; Muhammad Yasir, e-mail: muhammad.yasir@chem.uol.edu.pk
Doi # https://doi.org/10.62877/4-IJCBS-24-26-20-4
International Scientific Organization- Atom to Universe
Journals
- International Scientific Organization
- International Journal of Chemical and Biochemical Sciences (IJCBS)
- Volume 26 (2024)
- Volume 25 (2024)
- Volume 24 (2023)
- Volume 23 (2023)
- Volume 22 (2022)
- Volume 21 (2022)
- Volume 20 (2021)
- Volume 19 (2021)
- Volume 18 (2020)
- Volume 17 (2020)
- Volume 16 (2019)
- Volume 15 (2019)
- Volume 10 (2016)
- Volume 14 (2018)
- Volume 13 (2018)
- Volume 12 (2017)
- Volume 11 (2017)
- Volume 9 (2016)
- Volume 8 (2015)
- Volume 7 (2015)
- Volume 6 (2014)
- Volume 5 (2014)
- Volume 4 (2013)
- Volume 3 (2013)
- Volume 2 (2012)
- Volume 1 (2012)
- Store
- Cart
- Account