International Journal of Chemical and Biochemical Sciences (ISSN 2226-9614)[/vc_column_text][/vc_column][/vc_row]
VOLUME 29(23) (2026)
Influence of Data Acquisition Techniques on the Retention of Removable Partial Denture Frameworks: An In Vitro Study
Ahmed Hussien Ahmed Hussien, Yasmine Said El-Sherbeeny Elsayed,
Sawsan Maged Fadl Aly
Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University,
Cairo, Egypt.
Abstract
To evaluate and compare retention of removable partial denture frameworks (RPD) manufactured via different data acquisition techniques; conventional impression, intraoral and extraoral scanning techniques. A partially edentulous maxillary resin model representing a Kennedy class III modification 1 with the first premolars and second molars bilaterally as abutments was three dimensionally (3D) printed. Upon which RPD frameworks were manufactured via three data acquisition approaches, hence three groups were identified: Group A (conventional impression with the traditional lost-wax technique); Group B (intraoral digital impression combined with 3D-printed wax patterns and the lost-wax technique); and Group C (extraoral digital scanning of physical casts combined with 3D-printed wax patterns and the lost-wax technique). Retention was subsequently evaluated using a universal testing machine. Intergroup comparison was done using one-way ANOVA followed by Tukey’s test. Normality and homogeneity of variance were examined using the Shapiro-Wilk and Levene’s tests, respectively. Intergroup comparison revealed a significant difference between different groups (P < .001), and the effect size was large (0.96). The highest retention was observed in the group C (27.67±0.94 N), followed by the Conventional group A (23.08±0.53 N), and the lowest in the Intraoral group B (17.90±1.11 N). All post hoc pairwise comparisons were statistically significant. Extraoral digital impression technique provided the highest initial retention followed by the conventional impression. However, the intraoral scanners provided the lowest initial retention. All groups provided clinically acceptable results.
Keywords: RPD framework, data acquisition, Intraoral scanner, Extraoral scanner, Retention.
Full length article *Corresponding Author, e-mail: Ahmedhussien.cr96@gmail.com; Doi # https://doi.org/10.62877/28-IJCBS-26-29-23-28
Submitted: 02-07-2026; Accepted: 22-08-2026; Published: 23-08-2026
International Scientific Organization- Atom to Universe
International Scientific Organization
- Home
- International Journal of Chemical and Biochemical Sciences (IJCBS) – HOME PAGE
- Editorial board
- Instructions to authors
- Volume 29 (2026)
- Volume 28 (2025)
- Volume 27 (2025)
- Volume 26 (2024)
- Volume 25 (2024)
- Volume 24 (2023)
- Volume 23 (2023)
- Volume 22 (2022)
- Volume 21 (2022)
- Volume 20 (2021)
- Volume 19 (2021)
- Volume 18 (2020)
- Volume 17 (2020)
- Volume 16 (2019)
- Volume 15 (2019)
- Volume 14 (2018)
- Volume 13 (2018)
- Volume 12 (2017)
- Volume 11 (2017)
- Volume 10 (2016)
- Volume 9 (2016)
- Volume 8 (2015)
- Volume 7 (2015)
- Volume 6 (2014)
- Volume 5 (2014)
- Volume 4 (2013)
- Volume 3 (2013)
- Volume 2 (2012)
- Volume 1 (2012)